Click on the Model for technical data, dimensions, accessories
PS-DC 2T - without casing, for horizontal concealed mounting inside ceiling, three-speed AC type centrifugal fan, ductable for static pressure up to 150 Pa, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-DC 2T 080 5.31/5.71/5.95 kW heating capacity or 4.13/4.44/4.61 kW cooling capacity in 3 row heat exchanger, air flow 710/780/830 m³/h, sound pressure level 42/44/45 dB(A), max. fan power 166 W, dimensions 700x620xH275 mm, weight 26 kg, 2 year WARRANTY
PS-DC 2T 080
5.31/5.71/5.95 kW heating capacity or 4.13/4.44/4.61 kW cooling capacity in 3 row heat exchanger, air flow 710/780/830 m³/h, sound pressure level 42/44/45 dB(A), max. fan power 166 W, dimensions 700x620xH275 mm, weight 26 kg, 2 year WARRANTY
PS-DC 2T 110 6.71/7.35/7.98 kW heating capacity or 5.72/6.18/6.68 kW cooling capacity in 3 row heat exchanger, air flow 800/895/990 m³/h, sound pressure level 42/45/47 dB(A), max. fan power 184 W, dimensions 900x620xH275 mm, weight 29.5 kg, 2 year WARRANTY
PS-DC 2T 110
6.71/7.35/7.98 kW heating capacity or 5.72/6.18/6.68 kW cooling capacity in 3 row heat exchanger, air flow 800/895/990 m³/h, sound pressure level 42/45/47 dB(A), max. fan power 184 W, dimensions 900x620xH275 mm, weight 29.5 kg, 2 year WARRANTY
PS-DC 2T 140 11.08/11.79/12.33 kW heating capacity or 9.05/9.61/9.98 kW cooling capacity in 3 row heat exchanger, air flow 1460/1585/1680 m³/h, sound pressure level 44/46/48 dB(A), max. fan power 340 W, dimensions 1100x620xH275 mm, weight 36 kg, 2 year WARRANTY
PS-DC 2T 140
11.08/11.79/12.33 kW heating capacity or 9.05/9.61/9.98 kW cooling capacity in 3 row heat exchanger, air flow 1460/1585/1680 m³/h, sound pressure level 44/46/48 dB(A), max. fan power 340 W, dimensions 1100x620xH275 mm, weight 36 kg, 2 year WARRANTY
PS-DC 2T 160 12.22/13.22/14.01 kW heating capacity or 10.09/10.83/11.46 kW cooling capacity in 3 row heat exchanger, air flow 1550/1715/1850 m³/h, sound pressure level 45/47/49 dB(A), max. fan power 350 W, dimensions 1300x620xH275 mm, weight 42 kg, 2 year WARRANTY
PS-DC 2T 160
12.22/13.22/14.01 kW heating capacity or 10.09/10.83/11.46 kW cooling capacity in 3 row heat exchanger, air flow 1550/1715/1850 m³/h, sound pressure level 45/47/49 dB(A), max. fan power 350 W, dimensions 1300x620xH275 mm, weight 42 kg, 2 year WARRANTY
PS-DC 2T 220 16.33/17.39/18.32 kW heating capacity or 13.35/14.13/14.82 kW cooling capacity in 3 row heat exchanger, air flow 2140/2320/2490 m³/h, sound pressure level 47/49/50 dB(A), max. fan power 500 W, dimensions 1500x620xH275 mm, weight 55 kg, 2 year WARRANTY
PS-DC 2T 220
16.33/17.39/18.32 kW heating capacity or 13.35/14.13/14.82 kW cooling capacity in 3 row heat exchanger, air flow 2140/2320/2490 m³/h, sound pressure level 47/49/50 dB(A), max. fan power 500 W, dimensions 1500x620xH275 mm, weight 55 kg, 2 year WARRANTY
PS-DC 4T - without casing, for horizontal concealed mounting inside ceiling, three-speed AC type centrifugal fan, ductable for static pressure up to 150 Pa, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-DC 4T 084 4.42/4.45/4.74 kW heating capacity in 1 row heat exchanger and 4.13/4.44/4.61 kW cooling capacity in 3 row heat exchanger, air flow 710/780/830 m³/h, sound pressure level 42/44/45 dB(A), max. fan power 166 W, dimensions 700x620xH275 mm, weight 26 kg, 2 year WARRANTY
PS-DC 4T 084
4.42/4.45/4.74 kW heating capacity in 1 row heat exchanger and 4.13/4.44/4.61 kW cooling capacity in 3 row heat exchanger, air flow 710/780/830 m³/h, sound pressure level 42/44/45 dB(A), max. fan power 166 W, dimensions 700x620xH275 mm, weight 26 kg, 2 year WARRANTY
PS-DC 4T 114 5.61/6.04/6.42 kW heating capacity in 1 row heat exchanger and 5.72/6.18/6.68 kW cooling capacity in 3 row heat exchanger, air flow 800/895/990 m³/h, sound pressure level 42/45/47 dB(A), max. fan power 184 W, dimensions 900x620xH275 mm, weight 29.5 kg, 2 year WARRANTY
PS-DC 4T 114
5.61/6.04/6.42 kW heating capacity in 1 row heat exchanger and 5.72/6.18/6.68 kW cooling capacity in 3 row heat exchanger, air flow 800/895/990 m³/h, sound pressure level 42/45/47 dB(A), max. fan power 184 W, dimensions 900x620xH275 mm, weight 29.5 kg, 2 year WARRANTY
PS-DC 4T 144 8.72/9.26/9.59 kW heating capacity in 1 row heat exchanger and 9.05/9.61/9.98 kW cooling capacity in 3 row heat exchanger, air flow 1460/1585/1680 m³/h, sound pressure level 44/46/48 dB(A), max. fan power 340 W, dimensions 1100x620xH275 mm, weight 36 kg, 2 year WARRANTY
PS-DC 4T 144
8.72/9.26/9.59 kW heating capacity in 1 row heat exchanger and 9.05/9.61/9.98 kW cooling capacity in 3 row heat exchanger, air flow 1460/1585/1680 m³/h, sound pressure level 44/46/48 dB(A), max. fan power 340 W, dimensions 1100x620xH275 mm, weight 36 kg, 2 year WARRANTY
PS-DC 4T 164 10.06/10.68/11.28 kW heating capacity in 1 row heat exchanger and 10.09/10.83/11.46 kW cooling capacity in 3 row heat exchanger, air flow 1550/1715/1850 m³/h, sound pressure level 45/47/49 dB(A), max. fan power 350 W, dimensions 1300x620xH275 mm, weight 42 kg, 2 year WARRANTY
PS-DC 4T 164
10.06/10.68/11.28 kW heating capacity in 1 row heat exchanger and 10.09/10.83/11.46 kW cooling capacity in 3 row heat exchanger, air flow 1550/1715/1850 m³/h, sound pressure level 45/47/49 dB(A), max. fan power 350 W, dimensions 1300x620xH275 mm, weight 42 kg, 2 year WARRANTY
PS-DC 4T 224 12.50/12.95/13.57 kW heating capacity in 1 row heat exchanger and 13.35/14.13/14.82 kW cooling capacity in 3 row heat exchanger, air flow 2140/2320/2490 m³/h, sound pressure level 47/49/50 dB(A), max. fan power 500 W, dimensions 1500x620xH275 mm, weight 55 kg, 2 year WARRANTY
PS-DC 4T 224
12.50/12.95/13.57 kW heating capacity in 1 row heat exchanger and 13.35/14.13/14.82 kW cooling capacity in 3 row heat exchanger, air flow 2140/2320/2490 m³/h, sound pressure level 47/49/50 dB(A), max. fan power 500 W, dimensions 1500x620xH275 mm, weight 55 kg, 2 year WARRANTY
PS-DCE 2T - without casing, for horizontal concealed mounting inside ceiling, EC type centrifugal fan, ductable for static pressure up to 150 Pa, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-DCE 2T 080 2.88/5.03/5.55 kW heating capacity or 2.17/3.78/4.16 kW cooling capacity in 3 row heat exchanger, air flow 407/832/948 m³/h, sound pressure level 32/43/46 dB(A), max. fan power 154 W, dimensions 700x620xH275 mm, weight 28 kg, 2 year WARRANTY
PS-DCE 2T 080
2.88/5.03/5.55 kW heating capacity or 2.17/3.78/4.16 kW cooling capacity in 3 row heat exchanger, air flow 407/832/948 m³/h, sound pressure level 32/43/46 dB(A), max. fan power 154 W, dimensions 700x620xH275 mm, weight 28 kg, 2 year WARRANTY
PS-DCE 2T 110 3.69/6.60/7.49 kW heating capacity or 2.76/4.97/5.63 kW cooling capacity in 3 row heat exchanger, air flow 502/1049/1238 m³/h, sound pressure level 29/43/48 dB(A), max. fan power 200 W, dimensions 900x620xH275 mm, weight 31.5 kg, 2 year WARRANTY
PS-DCE 2T 110
3.69/6.60/7.49 kW heating capacity or 2.76/4.97/5.63 kW cooling capacity in 3 row heat exchanger, air flow 502/1049/1238 m³/h, sound pressure level 29/43/48 dB(A), max. fan power 200 W, dimensions 900x620xH275 mm, weight 31.5 kg, 2 year WARRANTY
PS-DCE 2T 140 3.94/7.26/8.91 kW heating capacity or 2.91/5.48/6.71 kW cooling capacity in 3 row heat exchanger, air flow 514/1091/1422 m³/h, sound pressure level 30/44/51 dB(A), max. fan power 221 W, dimensions 1100x620xH275 mm, weight 38 kg, 2 year WARRANTY
PS-DCE 2T 140
3.94/7.26/8.91 kW heating capacity or 2.91/5.48/6.71 kW cooling capacity in 3 row heat exchanger, air flow 514/1091/1422 m³/h, sound pressure level 30/44/51 dB(A), max. fan power 221 W, dimensions 1100x620xH275 mm, weight 38 kg, 2 year WARRANTY
PS-DCE 2T 160 6.29/9.36/11.07 kW heating capacity or 4.96/7.32/8.62 kW cooling capacity in 3 row heat exchanger, air flow 840/1384/1718 m³/h, sound pressure level 34/42/47 dB(A), max. fan power 165 W, dimensions 1300x620xH275 mm, weight 44 kg, 2 year WARRANTY
PS-DCE 2T 160
6.29/9.36/11.07 kW heating capacity or 4.96/7.32/8.62 kW cooling capacity in 3 row heat exchanger, air flow 840/1384/1718 m³/h, sound pressure level 34/42/47 dB(A), max. fan power 165 W, dimensions 1300x620xH275 mm, weight 44 kg, 2 year WARRANTY
PS-DCE 2T 220 8.33/13.74/15.80 kW heating capacity or 6.52/10.63/12.18 kW cooling capacity in 3 row heat exchanger, air flow 1144/2162/2595 m³/h, sound pressure level 35/48/53 dB(A), max. fan power 400 W, dimensions 1500x620xH275 mm, weight 57 kg, 2 year WARRANTY
PS-DCE 2T 220
8.33/13.74/15.80 kW heating capacity or 6.52/10.63/12.18 kW cooling capacity in 3 row heat exchanger, air flow 1144/2162/2595 m³/h, sound pressure level 35/48/53 dB(A), max. fan power 400 W, dimensions 1500x620xH275 mm, weight 57 kg, 2 year WARRANTY
PS-DCE 4T - without casing, for horizontal concealed mounting inside ceiling, EC type centrifugal fan, ductable for static pressure up to 150 Pa, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-DCE 4T 084 2.07/3.29/3.60 kW heating capacity in 1 row heat exchanger and 2.17/3.78/4.16 kW cooling capacity in 3 row heat exchanger, air flow 407/832/948 m³/h, sound pressure level 32/43/47 dB(A), max. fan power 154 W, dimensions 700x620xH275 mm, weight 28 kg, 2 year WARRANTY
PS-DCE 4T 084
2.07/3.29/3.60 kW heating capacity in 1 row heat exchanger and 2.17/3.78/4.16 kW cooling capacity in 3 row heat exchanger, air flow 407/832/948 m³/h, sound pressure level 32/43/47 dB(A), max. fan power 154 W, dimensions 700x620xH275 mm, weight 28 kg, 2 year WARRANTY
PS-DCE 4T 114 2.85/4.63/5.16 kW heating capacity in 1 row heat exchanger and 2.76/4.97/5.63 kW cooling capacity in 3 row heat exchanger, air flow 502/1049/1238 m³/h, sound pressure level 29/43/48 dB(A), max. fan power 200 W, dimensions 900x620xH275 mm, weight 31.5 kg, 2 year WARRANTY
PS-DCE 4T 114
2.85/4.63/5.16 kW heating capacity in 1 row heat exchanger and 2.76/4.97/5.63 kW cooling capacity in 3 row heat exchanger, air flow 502/1049/1238 m³/h, sound pressure level 29/43/48 dB(A), max. fan power 200 W, dimensions 900x620xH275 mm, weight 31.5 kg, 2 year WARRANTY
PS-DCE 4T 144 3.06/5.02/5.95 kW heating capacity in 1 row heat exchanger and 2.91/5.47/6.71 kW cooling capacity in 3 row heat exchanger, air flow 514/1091/1422 m³/h, sound pressure level 30/44/51 dB(A), max. fan power 221 W, dimensions 1100x620xH275 mm, weight 38 kg, 2 year WARRANTY
PS-DCE 4T 144
3.06/5.02/5.95 kW heating capacity in 1 row heat exchanger and 2.91/5.47/6.71 kW cooling capacity in 3 row heat exchanger, air flow 514/1091/1422 m³/h, sound pressure level 30/44/51 dB(A), max. fan power 221 W, dimensions 1100x620xH275 mm, weight 38 kg, 2 year WARRANTY
PS-DCE 4T 164 4.69/6.51/7.49 kW heating capacity in 1 row heat exchanger and 4.96/7.32/8.62 kW cooling capacity in 3 row heat exchanger, air flow 840/1384/1718 m³/h, sound pressure level 34/42/47 dB(A), max. fan power 165 W, dimensions 1300x620xH275 mm, weight 44 kg, 2 year WARRANTY
PS-DCE 4T 164
4.69/6.51/7.49 kW heating capacity in 1 row heat exchanger and 4.96/7.32/8.62 kW cooling capacity in 3 row heat exchanger, air flow 840/1384/1718 m³/h, sound pressure level 34/42/47 dB(A), max. fan power 165 W, dimensions 1300x620xH275 mm, weight 44 kg, 2 year WARRANTY
PS-DCE 4T 224 6.21/9.43/10.65 kW heating capacity in 1 row heat exchanger and 6.52/10.63/12.18 kW cooling capacity in 3 row heat exchanger, air flow 1144/2162/2595 m³/h, sound pressure level 35/48/53 dB(A), max. fan power 400 W, dimensions 1500x620xH275 mm, weight 57 kg, 2 year WARRANTY
PS-DCE 4T 224
6.21/9.43/10.65 kW heating capacity in 1 row heat exchanger and 6.52/10.63/12.18 kW cooling capacity in 3 row heat exchanger, air flow 1144/2162/2595 m³/h, sound pressure level 35/48/53 dB(A), max. fan power 400 W, dimensions 1500x620xH275 mm, weight 57 kg, 2 year WARRANTY
PS-DC / PS-DCE ductable up to 150 Pa concealed fan coil units