Gas absorption heat pump, reversible, on heating operation mode takes heat from Air and gives it to Water for heating, on cooling operation mode takes heat from Water for cooling and gives it to Air, connected with additional condensing boiler, supplied as standard with 4 pipes hydraulic connection (at additional cost can be ordered with 2 pipes hydraulic connection), maximum outlet water temperature for heating/DHW 60/80°C, heat pump heating capacity 37.8 kW (A7/W35), heat pump G.U.E. gas utilization efficiency for heating 150% (A7/W35), condensing boiler heating capacity 34.4 kW (80/60°C), condensing boiler efficiency 104.6% (50/30°C), A+ energy class ErP on 55°C operation, minimum outlet water temperature for cooling 3°C, heat pump cooling capacity 16.9 kW (A35/W7), heat pump G.U.E. gas utilization efficiency for cooling 67% (A35/W7), gas (G20) consumption 6.36 m³/h, electrical power consumption 0.95 kW, sound pressure level (at 5 m distance) 53.0 dB(A), electrical degree of protection IP X5D, weight empty / full 490/515 kg, outside working temperature in heating mode -20°C/+45°C (can be ordered with special winter kit for operation on lower temperature down to -30°C), outside working temperature in cooling mode 0°C/+45°C
Interested in this product? Contact us:

Linas Skauminas

LT, EN
+370 671 56675

Head of the company,
design consulting
Get Offer
Click on the Model for technical data, dimensions, accessories
GITIE-ARAY - reversible, on heating operation mode takes heat from Air and gives it to Water for heating, on cooling operation mode takes heat from Water for cooling and gives it to Air, connected with additional condensing boiler, supplied as standard with 4 pipes hydraulic connection (at additional cost can be ordered with 2 pipes hydraulic connection)
GITIE-ARAY STANDARD Maximum outlet water temperature for heating/DHW 60/80°C, heat pump heating capacity 37.8 kW (A7/W35), heat pump G.U.E. gas utilization efficiency for heating 150% (A7/W35), condensing boiler heating capacity 34.4 kW (80/60°C), condensing boiler efficiency 104.6% (50/30°C), A+ energy class ErP on 55°C operation, minimum outlet water temperature for cooling 3°C, heat pump cooling capacity 16.9 kW (A35/W7), heat pump G.U.E. gas utilization efficiency for cooling 67% (A35/W7), gas (G20) consumption 6.36 m³/h, electrical power consumption 1.025 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight empty / full 480/505 kg, outside working temperature in heating mode -20°C/+45°C (can be ordered with special winter kit for operation on lower temperature down to -30°C), outside working temperature in cooling mode 0°C/+45°C
GITIE-ARAY STANDARD
Maximum outlet water temperature for heating/DHW 60/80°C, heat pump heating capacity 37.8 kW (A7/W35), heat pump G.U.E. gas utilization efficiency for heating 150% (A7/W35), condensing boiler heating capacity 34.4 kW (80/60°C), condensing boiler efficiency 104.6% (50/30°C), A+ energy class ErP on 55°C operation, minimum outlet water temperature for cooling 3°C, heat pump cooling capacity 16.9 kW (A35/W7), heat pump G.U.E. gas utilization efficiency for cooling 67% (A35/W7), gas (G20) consumption 6.36 m³/h, electrical power consumption 1.025 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight empty / full 480/505 kg, outside working temperature in heating mode -20°C/+45°C (can be ordered with special winter kit for operation on lower temperature down to -30°C), outside working temperature in cooling mode 0°C/+45°C
GITIE-ARAY LOW-NOISE Maximum outlet water temperature for heating/DHW 60/80°C, heat pump heating capacity 37.8 kW (A7/W35), heat pump G.U.E. gas utilization efficiency for heating 150% (A7/W35), condensing boiler heating capacity 34.4 kW (80/60°C), condensing boiler efficiency 104.6% (50/30°C), A+ energy class ErP on 55°C operation, minimum outlet water temperature for cooling 3°C, heat pump cooling capacity 16.9 kW (A35/W7), heat pump G.U.E. gas utilization efficiency for cooling 67% (A35/W7), gas (G20) consumption 6.36 m³/h, electrical power consumption 0.95 kW, sound pressure level (at 5 m distance) 53.0 dB(A), electrical degree of protection IP X5D, weight empty / full 490/515 kg, outside working temperature in heating mode -20°C/+45°C (can be ordered with special winter kit for operation on lower temperature down to -30°C), outside working temperature in cooling mode 0°C/+45°C
GITIE-ARAY LOW-NOISE
Maximum outlet water temperature for heating/DHW 60/80°C, heat pump heating capacity 37.8 kW (A7/W35), heat pump G.U.E. gas utilization efficiency for heating 150% (A7/W35), condensing boiler heating capacity 34.4 kW (80/60°C), condensing boiler efficiency 104.6% (50/30°C), A+ energy class ErP on 55°C operation, minimum outlet water temperature for cooling 3°C, heat pump cooling capacity 16.9 kW (A35/W7), heat pump G.U.E. gas utilization efficiency for cooling 67% (A35/W7), gas (G20) consumption 6.36 m³/h, electrical power consumption 0.95 kW, sound pressure level (at 5 m distance) 53.0 dB(A), electrical degree of protection IP X5D, weight empty / full 490/515 kg, outside working temperature in heating mode -20°C/+45°C (can be ordered with special winter kit for operation on lower temperature down to -30°C), outside working temperature in cooling mode 0°C/+45°C
Model: GITIE-ARAY LOW-NOISE
Heating operation mode data
Energy class (55°C operation)
ErP
A+
Heat pump G.U.E. gas utilization efficiency at 35°C water and 7°C air temperature
%
150
Heat pump heating capacity at 35°C water and 7°C air temperature
kW
37,8
Condensing boiler efficiency at 50/30°C water temperature
%
104,6
Condensing boiler heating capacity at 80/60°C water temperature
kW
34,4
Maximum outlet water temperature (heating / DHW)
°C
60 / 80
Maximum inlet water temperature (heating / DHW)
°C
50 / 70
Operating temperature range
°C
-20 / +45
Operating temperature range with winter kit
°C
-30 / +45
Cooling operation mode data
G.U.E. gas utilization efficiency at 7°C water and 35°C air temperature
%
67
Cooling capacity at 7°C water and 35°C air temperature
kW
16,9
Minimum outlet water temperature
°C
+3
Minimum / Maximum inlet water temperature
°C
+6 / +45
Operating temperature range
°C
0 / +45
Burner characteristics
Thermal input (actual)
kW
60,1
Natural gas (G20) consumption at 15 °C - 1013 mbar
m³/h
6,36
LPG G30 / G31 consumption at 15 °C - 1013 mbar
kg/h
4,71
Installation data
Power supply
V/Hz
230/50
Nominal electrical power consumption
kW
0,95
Sound pressure at 5 meters distance from unit front side in free field
dB(A)
53,0
IP protection class
X5D
Hydraulic connection (4 pipes version)
Ø "
F 1 1/4
Hydraulic connection (2 pipes version)
Ø "
F 1 1/2
Gas connection
Ø "
M 3/4
Exhaust air flue diameter (heat pump)
mm Ø
80
Exhaust air flue diameter (condensing boiler)
mm Ø
80
Dimensions
Width
mm
1356
Depth
mm
1260
Height
mm
1540
Weight of unit filled with water
kg
515
Weight without water
kg
490

Dimensions

Model: GITIE-ARAY LOW-NOISE

Gas powered reversible absorption heat pump with additional condensing boiler GITIE-ARAY is designed for high efficiency heating, domestic hot water production up to 80°C and cooling with low electric energy consumption.

Gitié is the perfect blend of two winning technologies: the airsource absorption heat pump and the condensing boiler, both powered by natural gas. Gitié can provide up to 3 services:

  • high efficiency heating;
  • hot water production up to 80°C;
  • cooling with low electric energy consumption.

Advantages

  • Gitié, integrated, preassembled and custommade in the manufacturing plant, is a fully plug-‘n-play system. This can facilitate correct installation, avoiding the complexity of the integration on field of solar thermal systems.
  • Gitié is the all-in-one solution replacing a boiler + solar thermal system using airsource renewable energy available 24-hours-a-day. For each kW of natural gas equivalent used, Gitié adds 0.5 kW of renewable energy.
  • Gitié capital cost is convenient and it provides up to 40% of running cost savings if compared with similar solutions.
  • It is eligible for national and local incentive programs all over Europe.
  • Use of natural refrigerants not subject to normal constraints and phase-out (F-Gas Regulation exempt).

Applications

  • Ideal for residential, industrial, commercial and hospitality facilities.
  • Suitable for both new and existing buildings as it’s for fitting in heating systems with low temperature (radiant heating or fan coils) or high temperature (radiators) distribution systems.
  • Outdoor installation.

Versions

  • Available in standard or low noise version, 2 and 4 pipes, with or without modulating circulators.

GITIE-ARAY is a trivalent integrated outdoor package comprising of:

  • air-source reversible gas absorption heat pump GAHP-AR;
  • condensing boiler AY.

Standard configuration

  • 4-pipe service plate for water and gas connections.
  • Electrical box for:
    • external control systems connections (like room thermostats, timers etc.);
    • Direct Digital Control (optional) connection;
    • water pumps connection.
  • Steel rail.

Low noise version

With low-noise fan unit and a special sound-proof insulated casing. Ideal for installations where noise reduction is required.

Hydraulic kit

  • 2 pipes (KIT /2 C0):
    • Single water loop;
    • Two motorized and factory wired check valves to optimize the efficiency of the system
  • 2 pipes with circulators (KIT /2 C1):
    • Single water loop with circulators;
    • Two high efficiency and factory wired circulators (ErP Directive) to optimize the water flow and efficiency of the system.
  • 4 pipes with circulators (KIT /4 C1):
    • Two independent water loops with circulators;
    • Two high efficiency and factory wired circulators (ErP Directive) to optimize the water flow of the system.

Accessories

  • Direct Digital Control for a smart system management.
  • RoburBox100 for a smart control interface of cooling and domestic hot production management (Direct Digital Control required).
  • Outdoor temperature probe.
  • CAN BUS cable.
  • High efficiency circulators (ErP Directive) with increased pressure head.
  • Vibration dampers.
  • Gas/LPG conversion kit.
GITIE-ARAY reversible gas absorption heat pump Air/Water with additional condensing boiler
Manuals 9.3 MB
Declarations of conformity 1.3 MB
Catalogue 6.4 MB
DDC control panel