Interested in this product? Contact us: Get Offer
Click on the Model for technical data, dimensions, accessories
EOLO NBC AE MIX - for external installation on wall or roof, fully insulated casing, non-condensing version, with axial fan for free blowing inside room, pre-mix burner
EOLO NBC 25 AE MIX 15-22 kW modulating thermal power capacity, air flow 2900 m³/h, air throw 13 m, fan power 0.26 kW, max. gas (G20) consumption 2.33 m³/h, weight 62 kg, 2 year WARRANTY
EOLO NBC 25 AE MIX
15-22 kW modulating thermal power capacity, air flow 2900 m³/h, air throw 13 m, fan power 0.26 kW, max. gas (G20) consumption 2.33 m³/h, weight 62 kg, 2 year WARRANTY
EOLO NBC 35 AE MIX 20-32 kW modulating thermal power capacity, air flow 3600 m³/h, air throw 17 m, fan power 0.35 kW, max. gas (G20) consumption 3.39 m³/h, weight 74 kg, 2 year WARRANTY
EOLO NBC 35 AE MIX
20-32 kW modulating thermal power capacity, air flow 3600 m³/h, air throw 17 m, fan power 0.35 kW, max. gas (G20) consumption 3.39 m³/h, weight 74 kg, 2 year WARRANTY
EOLO NBC 45 AE MIX 28-43 kW modulating thermal power capacity, air flow 4500 m³/h, air throw 19 m, fan power 0.56 kW, max. gas (G20) consumption 4.55 m³/h, weight 89 kg, 2 year WARRANTY
EOLO NBC 45 AE MIX
28-43 kW modulating thermal power capacity, air flow 4500 m³/h, air throw 19 m, fan power 0.56 kW, max. gas (G20) consumption 4.55 m³/h, weight 89 kg, 2 year WARRANTY
EOLO NBC 55 AE MIX 34-52 kW modulating thermal power capacity, air flow 5800 m³/h, air throw 23 m, fan power 0.71 kW, max. gas (G20) consumption 5.5 m³/h, weight 118 kg, 2 year WARRANTY
EOLO NBC 55 AE MIX
34-52 kW modulating thermal power capacity, air flow 5800 m³/h, air throw 23 m, fan power 0.71 kW, max. gas (G20) consumption 5.5 m³/h, weight 118 kg, 2 year WARRANTY
EOLO NBC 65 AE MIX 42-63 kW modulating thermal power capacity, air flow 7000 m³/h, air throw 25 m, fan power 0.69 kW, max. gas (G20) consumption 6.67 m³/h, weight 128 kg, 2 year WARRANTY
EOLO NBC 65 AE MIX
42-63 kW modulating thermal power capacity, air flow 7000 m³/h, air throw 25 m, fan power 0.69 kW, max. gas (G20) consumption 6.67 m³/h, weight 128 kg, 2 year WARRANTY
EOLO NBC 85 AE MIX 56-86 kW modulating thermal power capacity, air flow 9000 m³/h, air throw 27 m, fan power 1.12 kW, max. gas (G20) consumption 9.1 m³/h, weight 148 kg, 2 year WARRANTY
EOLO NBC 85 AE MIX
56-86 kW modulating thermal power capacity, air flow 9000 m³/h, air throw 27 m, fan power 1.12 kW, max. gas (G20) consumption 9.1 m³/h, weight 148 kg, 2 year WARRANTY
EOLO NBC 100 AE MIX 71-105 kW modulating thermal power capacity, air flow 11000 m³/h, air throw 30 m, fan power 1.48 kW, max. gas (G20) consumption 11.11 m³/h, weight 186 kg, 2 year WARRANTY
EOLO NBC 100 AE MIX
71-105 kW modulating thermal power capacity, air flow 11000 m³/h, air throw 30 m, fan power 1.48 kW, max. gas (G20) consumption 11.11 m³/h, weight 186 kg, 2 year WARRANTY
EOLO BC AE MIX - for external installation on wall or roof, fully insulated casing, condensing version, with axial fan for free blowing inside room, pre-mix burner
EOLO BC 25 AE MIX 8-22 kW modulating thermal power capacity, air flow 2900 m³/h, air throw 13 m, fan power 0.26 kW, max. gas (G20) consumption 2.33 m³/h, weight 62 kg, 2 year WARRANTY
EOLO BC 25 AE MIX
8-22 kW modulating thermal power capacity, air flow 2900 m³/h, air throw 13 m, fan power 0.26 kW, max. gas (G20) consumption 2.33 m³/h, weight 62 kg, 2 year WARRANTY
EOLO BC 35 AE MIX 11-32 kW modulating thermal power capacity, air flow 3600 m³/h, air throw 17 m, fan power 0.35 kW, max. gas (G20) consumption 3.39 m³/h, weight 74 kg, 2 year WARRANTY
EOLO BC 35 AE MIX
11-32 kW modulating thermal power capacity, air flow 3600 m³/h, air throw 17 m, fan power 0.35 kW, max. gas (G20) consumption 3.39 m³/h, weight 74 kg, 2 year WARRANTY
EOLO BC 45 AE MIX 15-43 kW modulating thermal power capacity, air flow 4500 m³/h, air throw 19 m, fan power 0.56 kW, max. gas (G20) consumption 4.55 m³/h, weight 89 kg, 2 year WARRANTY
EOLO BC 45 AE MIX
15-43 kW modulating thermal power capacity, air flow 4500 m³/h, air throw 19 m, fan power 0.56 kW, max. gas (G20) consumption 4.55 m³/h, weight 89 kg, 2 year WARRANTY
EOLO BC 55 AE MIX 18-52 kW modulating thermal power capacity, air flow 5800 m³/h, air throw 23 m, fan power 0.71 kW, max. gas (G20) consumption 5.5 m³/h, weight 118 kg, 2 year WARRANTY
EOLO BC 55 AE MIX
18-52 kW modulating thermal power capacity, air flow 5800 m³/h, air throw 23 m, fan power 0.71 kW, max. gas (G20) consumption 5.5 m³/h, weight 118 kg, 2 year WARRANTY
EOLO BC 65 AE MIX 22-63 kW modulating thermal power capacity, air flow 7000 m³/h, air throw 25 m, fan power 0.69 kW, max. gas (G20) consumption 6.67 m³/h, weight 128 kg, 2 year WARRANTY
EOLO BC 65 AE MIX
22-63 kW modulating thermal power capacity, air flow 7000 m³/h, air throw 25 m, fan power 0.69 kW, max. gas (G20) consumption 6.67 m³/h, weight 128 kg, 2 year WARRANTY
EOLO BC 85 AE MIX 28-86 kW modulating thermal power capacity, air flow 9000 m³/h, air throw 27 m, fan power 1.12 kW, max. gas (G20) consumption 9.1 m³/h, weight 148 kg, 2 year WARRANTY
EOLO BC 85 AE MIX
28-86 kW modulating thermal power capacity, air flow 9000 m³/h, air throw 27 m, fan power 1.12 kW, max. gas (G20) consumption 9.1 m³/h, weight 148 kg, 2 year WARRANTY
EOLO BC 100 AE MIX 32-103 kW modulating thermal power capacity, air flow 11000 m³/h, air throw 30 m, fan power 1.48 kW, max. gas (G20) consumption 11.11 m³/h, weight 186 kg, 2 year WARRANTY
EOLO BC 100 AE MIX
32-103 kW modulating thermal power capacity, air flow 11000 m³/h, air throw 30 m, fan power 1.48 kW, max. gas (G20) consumption 11.11 m³/h, weight 186 kg, 2 year WARRANTY
EOLO BC MIX external condensing gas fired heaters
Manuals 3.2 MB
Brochures 3.5 MB
Control panel user instructions 413 KB
Control panel manual 841 KB
AutoCAD drawings 10.5 MB
EOLO NBC MIX external non-condensing gas fired heaters
Manuals 6.6 MB
Brochures 3.5 MB
Control panel user instructions 413 KB
Control panel manual 841 KB
AutoCAD drawings 10.5 MB
SCM850 control panel
Manuals 751 KB
MODBUS protocol for connection to BMS 241 KB