Gas heater, with centrifugal fan for ducts system, pre-mix burner, 47.4 / 76.4 kW two steps heat output, air flow 6400 m³/h at 120 Pa, electrical power absorption 1.2 kW, max. gas (G20) consumption 8.89 m³/h, weight 129 kg, 2 year WARRANTY
Interested in this product? Contact us:

Arvydas Palivonas

LT, RU, EN
+370 601 74426

Sales representative for Vilnius, Ukmergė, Utena, Kaišiadorys and Varėna regions Get Offer

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Sales representative for Kaunas, Panevėžys, Šiauliai, Telšiai, Klaipėda, Tauragė, Marijampolė and Alytus districts Get Offer
Click on the Model for technical data, dimensions, accessories
NEXT-R C series - with centrifugal fan for ducts system, pre-mix burner
NEXT R30 C 15.8 / 25.5 kW two steps heat output, air flow 2000 m³/h at 120 Pa, electrical power absorption 0.3 kW, max. gas (G20) consumption 2.96 m³/h, weight 68 kg, 2 year WARRANTY
NEXT R30 C
15.8 / 25.5 kW two steps heat output, air flow 2000 m³/h at 120 Pa, electrical power absorption 0.3 kW, max. gas (G20) consumption 2.96 m³/h, weight 68 kg, 2 year WARRANTY
NEXT R40 C 21.6 / 35.0 kW two steps heat output, air flow 3200 m³/h at 120 Pa, electrical power absorption 0.6 kW, max. gas (G20) consumption 4.05 m³/h, weight 80 kg, 2 year WARRANTY
NEXT R40 C
21.6 / 35.0 kW two steps heat output, air flow 3200 m³/h at 120 Pa, electrical power absorption 0.6 kW, max. gas (G20) consumption 4.05 m³/h, weight 80 kg, 2 year WARRANTY
NEXT R50 C 29.1 / 44.6 kW two steps heat output, air flow 4500 m³/h at 180 Pa, electrical power absorption 0.85 kW, max. gas (G20) consumption 5.18 m³/h, weight 92 kg, 2 year WARRANTY
NEXT R50 C
29.1 / 44.6 kW two steps heat output, air flow 4500 m³/h at 180 Pa, electrical power absorption 0.85 kW, max. gas (G20) consumption 5.18 m³/h, weight 92 kg, 2 year WARRANTY
NEXT R80 C 47.4 / 76.4 kW two steps heat output, air flow 6400 m³/h at 120 Pa, electrical power absorption 1.2 kW, max. gas (G20) consumption 8.89 m³/h, weight 129 kg, 2 year WARRANTY
NEXT R80 C
47.4 / 76.4 kW two steps heat output, air flow 6400 m³/h at 120 Pa, electrical power absorption 1.2 kW, max. gas (G20) consumption 8.89 m³/h, weight 129 kg, 2 year WARRANTY
Model: NEXT R80 C
General data
Nominal heat output (min - max)
kW
50,4 - 84,0
Delivered thermal power (min. - max.)
kW
47,4 - 76,4
Efficiency (at min - max heating power)
%
94 - 91
Natural gas (G20) consumption at 15 °C - 1013 mbar
m³/h
8,89
LPG consumption at 15 °C - 1013 mbar
kg/h
6,62
Air flow at maximum allowed static pressure
m³/h
6400
Air flow at free blowing
m³/h
10700
Fan data
Static pressure
Pa
120
Minimal allowed static pressure drop on ducts
Pa
50
Installation data
Power supply
V/ph
230V 1N - 50 Hz
Power electric consumption
W
1200
Gas connection
Ø "
3/4 [F]
Operating temperature range
°C
0 / +35
Installation type
B23, C13, C33, C53, C63
Exhaust air flue diameter
mm Ø
80
Air Inlet flue diameter
mm Ø
80
Dimensions
Width
mm
1319
Depth
mm
1072
Height
mm
777
Weight
kg
129

Dimensions

Model: NEXT R80 C
NEXT-R two steps heat output gas fired heaters
Manuals 7.5 MB
Declarations of conformity 462 KB
Brochures 1.1 MB
Catalogue 1.6 MB
BIM objects 158.9 MB
OTRG005 thermoregulator
Manuals 3.8 MB
OCDS008 control panel
Manuals 2.8 MB
T-box controller
Manuals 5.7 MB
Declarations of conformity 643 KB
MODBUS protocol for connection to BMS 5.9 MB
DRV R control module for NEXT R gas fired heaters
Manuals 854 KB