Main roof module for air supply and extract unit with heat recovery and recirculation function, nominal air flow 8000 m³/h at 250 Pa, modulating energy saving EC fans, ePM2.5 65% (~F7) fresh air intake pocket filter, ePM10 50% (~M5) extracted room air cassette filter, 47 dB(A) sound pressure level at 10 m distance from unit, rotary heat exchanger with over 74.1% recuperation efficiency, recirculation damper ensures even regulation of fresh and recirculated air, Flowair control System with T-box Zone control panel allows devices to be connected to BMS, roof module weight ~600 kg, 2 years WARRANTY for all modules
Interested in this product? Contact us:

Arvydas Palivonas

LT, RU, EN
+370 601 74426

Sales representative for Vilnius, Ukmergė, Utena, Kaišiadorys and Varėna regions Get Offer

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Sales representative for Kaunas, Panevėžys, Šiauliai, Telšiai, Klaipėda, Tauragė, Marijampolė and Alytus districts Get Offer
Click on the Model for technical data, dimensions, accessories
Cube OV - modular air supply and extract unit with heat recovery and recirculation function
Cube OV Main roof module for air supply and extract unit with heat recovery and recirculation function, nominal air flow 8000 m³/h at 250 Pa, modulating energy saving EC fans, ePM2.5 65% (~F7) fresh air intake pocket filter, ePM10 50% (~M5) extracted room air cassette filter, 47 dB(A) sound pressure level at 10 m distance from unit, rotary heat exchanger with over 74.1% recuperation efficiency, recirculation damper ensures even regulation of fresh and recirculated air, Flowair control System with T-box Zone control panel allows devices to be connected to BMS, roof module weight ~600 kg, 2 years WARRANTY for all modules
Cube OV
Main roof module for air supply and extract unit with heat recovery and recirculation function, nominal air flow 8000 m³/h at 250 Pa, modulating energy saving EC fans, ePM2.5 65% (~F7) fresh air intake pocket filter, ePM10 50% (~M5) extracted room air cassette filter, 47 dB(A) sound pressure level at 10 m distance from unit, rotary heat exchanger with over 74.1% recuperation efficiency, recirculation damper ensures even regulation of fresh and recirculated air, Flowair control System with T-box Zone control panel allows devices to be connected to BMS, roof module weight ~600 kg, 2 years WARRANTY for all modules
Model: Cube OV
General data
Nominal air flow
m³/h
8000
Pressure drop at nominal air flow
Pa
250
Heat recovery - recuperation
Heat exchanger type
Rotary
Heat recovery efficiency
%
>74,1
Air filters data
Fresh air intake filter type
Pocket
Fresh air intake filter dimensions
mm
860x695x300
Fresh air intake filter class
ePM2.5 65% (~F7)
Extracted room air filter type
Cassette
Extracted room air filter dimensions
mm
800x592x50
Extracted room air filter class
ePM10 50% (~M5)
Construction data
Thermal insulation class (in accordance with PN-EN 13501-1)
M0
Material
AZ185
Housing colour
RAL 9007
Enclosure
50 mm sandwich panels
Insulation
mineral wool 90 m³/kg
Underframe
integrated steel
Main roof module weight
kg
~600
Electrical data
Power supply
V/Ph/Hz
400/3/50
Main roof module rated current
A
14,2
Main roof module rated power
kW
7,75
Acoustic data
Sound pressure level at a distance of 10 m from the unit
dB(A)
47

Optional gas heaters

Gas heater model Gm34 Gm45 Gm65
Nominal heat output kW 33,6 40,5 62,9
Gas consumption (G20) m3/h 3,69 4,44 6,88
Exhaust system integrated
Connection GZ ¾" GZ ¾" GZ ¾"
Minimum air flow rate m3/h 3500 4200 6500

Optional water exchangers

Water exchanger model W2, X2 W3, X3 W4, X4
Spigots 2x G1" 2x G1" 2x G1¼"
Capacity dm3 5,85 7,81 10,26
Rows 2 3 4
Max. working pressure - PS bar 16
Max. working temperature – TS ºC 90

Optional DX (Direct eXpansion) exchangers

DX exchanger model DX - FA2 DX - FA5
Air flow range m3/h 4000 - 8000 4000 - 8000
Dedicated condensing unit kW 28 56
Recommended temperature range before the exchanger in cooling (DB - Dry Bulb) ºC 18 - 13 18 - 13
Recommended temperature range before the exchanger in cooling (WB - Wet Bulb) ºC 32 - 23 32 - 24
Recommended temperature range before the heat exchanger in heating ºC 10 - 24 10 - 24
Fluid connection diameter 1/2” (12.7 mm) 5/8” (15.88 mm)
Gas nipple diameter 3/4” (19.05 mm) 1 1/8” (28.9 mm)
Capacity dm3 3,25 8,75
Max. working pressure - PS bar 42 42

Water exchangers heating capacity table

Heating capacity tabe (W) Text= -16°C Text= -16°C
Air flow Model Tz/Tp Qg Tnaw Dp mw Qg Tnaw dp mw
m3/val. - °C/°C kW °C kPa m3/val. kW °C kPa m3/val.
8000 W2 70/50 62,4 33,1 14,3 2,74 63,0 32,5 15,9 2,81
W3 60/40 68,7 35,3 9,5 3,01 70,8 35,3 10,1 3,10
W4 40/30 56,0 30,8 15,4 4,86 58,5 30,6 16,7 5,08
6000 W2 70/50 50,8 36,5 9,8 2,23 51,9 36,1 10,2 2,28
W3 60/40 54,2 38,2 6,2 2,37 55,7 37,9 6,5 2,44
W4 40/30 52,4 31,0 13,6 4,55 54,7 30,8 14,7 4,75
  • Air flow - amount of air flowing through the Cube OV
  • Text - outdoor air temperature - measured at the unit's air intake
  • Model - model of water heater [W2 - two-row, W3 - three-row, W4 - four-row]
  • Tnaw - supply air temperature
  • Tz/Tp - parameters of water supplying the exchanger
  • Qg - heating power of exchanger
  • Dp - hydraulic gradient on exchanger
  • mw - water flow through the exchanger

* The given parameters are for the following assumptions: supplying 100% fresh air, exhaust air with parameters 20°C/40%.

Cube OV construction
  1. Main roof module

    • smooth and automatic fan control
    • integrated automation system
    • certified heat recovery in a rotary heat exchanger
    • recirculated air damper
    • supply and exhaust air filters
  2. Condensing unit module

    • designed for use with DX (Direct eXpansion) exchanger
    • factory-mounted on the same frame as the main roof module
    • smooth power regulation
    • can be used in temperatures down to -25°C
    • reversible, can be used for both heating and cooling
  3. Gas heater module

    • smooth regulation of modulating heating power
    • convenient servicing on the roof of the building
  4. Roof transition module

    • This module is attached to the roof frame, which holds the entire structure of the unit
  5. Air distribution module

    • polluted room air is extracted through the side grille
    • a water heater can be installed inside (W2, W3, W4)
  6. Cooling / heating exchangers module

    • water cooling / heating exchanger (X2, X3, X4)
    • DX (Direct eXpansion) exchanger (DX-FA2, DX-FA5)
    • built-in condensate trap
  7. Air supply module

    • swirl diffuser with actuator and automatic adjustment (D)
    • long distance nozzles for high rooms (J)
    • ducted flow distributor for low rooms (V)
Cube OV modular ventilation unit with heat recovery and recirculation function
Manuals 1.9 MB
T-box Zone controller
Manuals 7.4 MB
Declarations of conformity 643 KB
MODBUS protocol for connection to BMS 1.8 MB