TER.ANA |
Control panel, suitable for 2-pipe and 4-pipe units with AC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SA, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH/CLQ, PS-UWL/UWLF/UWLV/UWLVF, PS-DC/DCV/HDC units |
|
TER.ANA |
|
Control panel, suitable for 2-pipe and 4-pipe units with AC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SA, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH/CLQ, PS-UWL/UWLF/UWLV/UWLVF, PS-DC/DCV/HDC units |
|
TER.DIG |
Control panel, suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SA, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH/CLQ, PS-UWL/UWLF/UWLV/UWLVF, PS-DC/DCV/HDC units |
|
TER.DIG |
|
Control panel, suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SA, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH/CLQ, PS-UWL/UWLF/UWLV/UWLVF, PS-DC/DCV/HDC units |
|
TER.BUS |
Control panel, suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional ? sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SA, possibility to connect supply hot water detection temperature sensor TM, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, RS485 connection to BMS via Modbus RTU protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH/CLQ, PS-UWL/UWLF/UWLV/UWLVF, PS-DC/DCV/HDC units |
|
TER.BUS |
|
Control panel, suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional ? sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SA, possibility to connect supply hot water detection temperature sensor TM, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, RS485 connection to BMS via Modbus RTU protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH/CLQ, PS-UWL/UWLF/UWLV/UWLVF, PS-DC/DCV/HDC units |
|
TER.BAC |
Control panel, suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional ? sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SA, possibility to connect supply hot water detection temperature sensor TM, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH/CLQ, PS-UWL/UWLF/UWLV/UWLVF, PS-DC/DCV/HDC units |
|
TER.BAC |
|
Control panel, suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional ? sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SA, possibility to connect supply hot water detection temperature sensor TM, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH/CLQ, PS-UWL/UWLF/UWLV/UWLVF, PS-DC/DCV/HDC units |
|
TER.TOUCH |
Control panel, suitable for 2-pipe units with AC fans, touch screen, manual and automatic 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, programmable weekly calendar, on/off valves control, possibility to connect remote air sensor SA, Wi-Fi connection for possibility to control the device remotely through the app for smart Android / IOS devices, for use with PS-FS, PS-FL/FLF/FLH 2T, PS-CL/CLH/CLQ 2T, PS-UWL/UWLF/UWLV/UWLVF 2T, PS-DC/DCV/HDC 2T units |
|
TER.TOUCH |
|
Control panel, suitable for 2-pipe units with AC fans, touch screen, manual and automatic 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, programmable weekly calendar, on/off valves control, possibility to connect remote air sensor SA, Wi-Fi connection for possibility to control the device remotely through the app for smart Android / IOS devices, for use with PS-FS, PS-FL/FLF/FLH 2T, PS-CL/CLH/CLQ 2T, PS-UWL/UWLF/UWLV/UWLVF 2T, PS-DC/DCV/HDC 2T units |
|
TER.TOUCH.Q |
Control panel, suitable for 2-pipe and 4-pipe units with AC fans, touch screen, integrated thermostat, automatic diffuser air outlet flaps movement control, for use with PS-CLQ units, required to use together with KIT.TEL.Q accessory |
|
TER.TOUCH.Q |
|
Control panel, suitable for 2-pipe and 4-pipe units with AC fans, touch screen, integrated thermostat, automatic diffuser air outlet flaps movement control, for use with PS-CLQ units, required to use together with KIT.TEL.Q accessory |
|
TEL.Q |
Wireless control panel, suitable for 2-pipe and 4-pipe units, LCD display, automatic diffuser air outlet flaps movement control, for use with PS-CLQ units, required to use together with KIT.TEL.Q accessory |
|
TEL.Q |
|
Wireless control panel, suitable for 2-pipe and 4-pipe units, LCD display, automatic diffuser air outlet flaps movement control, for use with PS-CLQ units, required to use together with KIT.TEL.Q accessory |
|
KIT.TEL.Q |
Unit control PCB, for installation inside fan coil unit with AC type fan, fits to PS-CLQ units with TER.TOUCH.Q, TEL.Q control panels, allows automatic diffuser air outlet flaps movement control |
|
KIT.TEL.Q |
|
Unit control PCB, for installation inside fan coil unit with AC type fan, fits to PS-CLQ units with TER.TOUCH.Q, TEL.Q control panels, allows automatic diffuser air outlet flaps movement control |
|
SCH.MBUS.Q |
Electronic board for PS-CLQ fan coil units diffusers air outlet flaps automatic control by BMS via RS485 ModBus protocol, required to use together with KIT.TEL.Q accessory |
|
SCH.MBUS.Q |
|
Electronic board for PS-CLQ fan coil units diffusers air outlet flaps automatic control by BMS via RS485 ModBus protocol, required to use together with KIT.TEL.Q accessory |
|
IDP |
Power interface distributor that allows to use single TER.ANA / TER.ANA.M / TER.ANA.S / TER.ANA.S.M / TER.DIG / TER.DIG.M / TER.DIG.D / TER.DIG.D.M / TER.DIG.S / TER.TOUCH / TER.TOUCH.M control panel for up to 4 fan coil units with AC type fans |
|
IDP |
|
Power interface distributor that allows to use single TER.ANA / TER.ANA.M / TER.ANA.S / TER.ANA.S.M / TER.DIG / TER.DIG.M / TER.DIG.D / TER.DIG.D.M / TER.DIG.S / TER.TOUCH / TER.TOUCH.M control panel for up to 4 fan coil units with AC type fans |
|
SW |
Supply water temperature sensor for automatic changeover of heating/cooling mode, to be used with 2-pipe units without valve or with 3-way valve, usable with TER.DIG / TER.DIG.M / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TER.EC.BAC.M control panels |
|
SW |
|
Supply water temperature sensor for automatic changeover of heating/cooling mode, to be used with 2-pipe units without valve or with 3-way valve, usable with TER.DIG / TER.DIG.M / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TER.EC.BAC.M control panels |
|
TM |
Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TER.EC.BAC.M / TEL + KIT.TEL / TEL + KIT.TEL.EC control panels |
|
TM |
|
Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TER.EC.BAC.M / TEL + KIT.TEL / TEL + KIT.TEL.EC control panels |
|
SA |
Air temperature probe for TER.ANA / TER.ANA.M / TER.EC.ANA / TER.EC.ANA.M / TER.DIG / TER.DIG.M / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TER.EC.BAC.M / TER.TOUCH / TER.EC.TOUCH control panels, used when the room temperature needs to be measured in a location other than the installed control panel |
|
SA |
|
Air temperature probe for TER.ANA / TER.ANA.M / TER.EC.ANA / TER.EC.ANA.M / TER.DIG / TER.DIG.M / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TER.EC.BAC.M / TER.TOUCH / TER.EC.TOUCH control panels, used when the room temperature needs to be measured in a location other than the installed control panel |
|
ATT.230 |
On/Off actuator for water valve, powered by 230 V |
|
ATT.230 |
|
On/Off actuator for water valve, powered by 230 V |
|
ATT.230.M |
On/Off actuator for water valve, powered by 230 V, with limit switch |
|
ATT.230.M |
|
On/Off actuator for water valve, powered by 230 V, with limit switch |
|
ATT.MOD |
Modulating by 0-10 V signal actuator for water valve |
|
ATT.MOD |
|
Modulating by 0-10 V signal actuator for water valve |
|
VAL.2V.34.CL |
2-way water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units, 3/4" connection |
|
VAL.2V.34.CL |
|
2-way water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units, 3/4" connection |
|
VAL.3V.34.CL |
3-way water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units, 3/4" connection |
|
VAL.3V.34.CL |
|
3-way water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units, 3/4" connection |
|
VAL.DIN.P.10.CLQ |
Balancing water valve for PS-CLQ fan coil units, 1" connection (3300 l/h) |
|
VAL.DIN.P.10.CLQ |
|
Balancing water valve for PS-CLQ fan coil units, 1" connection (3300 l/h) |
|
BAC.VAL1 |
Auxiliary drain pan for valve of PS-CL/CLE/CLES/CLH/CLEH/CLEHS/CLEI/CLQ fan coil units |
|
BAC.VAL1 |
|
Auxiliary drain pan for valve of PS-CL/CLE/CLES/CLH/CLEH/CLEHS/CLEI/CLQ fan coil units |
|
FL.RIN |
Fresh air inlet flange for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units |
|
FL.RIN |
|
Fresh air inlet flange for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units |
|
FL.AIR |
Flange for air supply to the adjacent room, fits PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units |
|
FL.AIR |
|
Flange for air supply to the adjacent room, fits PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units |
|
PAN.RAL.CLQ |
Painting of ABS plastic diffuser in non-standard RAL color for PS-CLQ fan coil units |
|
PAN.RAL.CLQ |
|
Painting of ABS plastic diffuser in non-standard RAL color for PS-CLQ fan coil units |