|
TER.EC.ANA |
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SA, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES/UWLED, PS-DCE/DCEV/HDCE units |
|
TER.EC.ANA |
|
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SA, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES/UWLED, PS-DCE/DCEV/HDCE units |
|
TER.EC.DIG |
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional ? sensor, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SA, possibility to connect supply hot water detection temperature sensor TM, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES/UWLED, PS-DCE/DCEV/HDCE units |
|
TER.EC.DIG |
|
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional ? sensor, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SA, possibility to connect supply hot water detection temperature sensor TM, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES/UWLED, PS-DCE/DCEV/HDCE units |
|
TER.EC.BUS |
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional ? sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SA, possibility to connect supply hot water detection temperature sensor TM, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, RS485 connection to BMS via Modbus RTU protocol, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES/UWLED, PS-DCE/DCEV/HDCE units |
|
TER.EC.BUS |
|
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional ? sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SA, possibility to connect supply hot water detection temperature sensor TM, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, RS485 connection to BMS via Modbus RTU protocol, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES/UWLED, PS-DCE/DCEV/HDCE units |
|
TER.EC.BAC |
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional ? sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SA, possibility to connect supply hot water detection temperature sensor TM, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES, PS-DCE/DCEV/HDCE units |
|
TER.EC.BAC |
|
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional ? sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SA, possibility to connect supply hot water detection temperature sensor TM, automatic changeover of heating/cooling mode for 2-pipe units if used with SW water temperature sensor, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES, PS-DCE/DCEV/HDCE units |
|
TEL |
Wireless control panel, suitable for 2-pipe and 4-pipe units, LCD display, manual and automatic 3 steps fan speed selection, manual summer/winter mode, on/off valves control, possibility to connect supply hot water detection temperature sensor TM, for use with PS-CL/CLE/CLES/CLH/CLEH/CLEHS/CLEI, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLEVF/UWLES, PS-DC/DCV/DCE/DCEV/HDC/HDCE units, required to use together with KIT.TEL or KIT.TEL.EC accessory |
|
TEL |
|
Wireless control panel, suitable for 2-pipe and 4-pipe units, LCD display, manual and automatic 3 steps fan speed selection, manual summer/winter mode, on/off valves control, possibility to connect supply hot water detection temperature sensor TM, for use with PS-CL/CLE/CLES/CLH/CLEH/CLEHS/CLEI, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLEVF/UWLES, PS-DC/DCV/DCE/DCEV/HDC/HDCE units, required to use together with KIT.TEL or KIT.TEL.EC accessory |
|
KIT.TEL.EC |
Wireless control panel signal receiver and unit control PCB together with temperature probe, for installation inside fan coil unit with EC type fan, fits to PS-CLE/CLES/CLEH/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES, PS-DCE/DCEV/HDCE units |
|
KIT.TEL.EC |
|
Wireless control panel signal receiver and unit control PCB together with temperature probe, for installation inside fan coil unit with EC type fan, fits to PS-CLE/CLES/CLEH/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES, PS-DCE/DCEV/HDCE units |
|
KIT.BUS |
Electronic board for PS-CLE/CLES/CLEH/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES/UWLED, PS-DCE/DCEV/HDCE fan coil units with EC fans connection to BMS via Modbus protocol, delivered with air temperature probe |
|
KIT.BUS |
|
Electronic board for PS-CLE/CLES/CLEH/CLEI, PS-UWLE/UWLEF/UWLEV/UWLEVF/UWLES/UWLED, PS-DCE/DCEV/HDCE fan coil units with EC fans connection to BMS via Modbus protocol, delivered with air temperature probe |
|
DIS.BUS |
Information screen to display data from device controlled via KIT.BUS electronic board |
|
DIS.BUS |
|
Information screen to display data from device controlled via KIT.BUS electronic board |
|
TM |
Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TER.EC.BAC.M / TEL + KIT.TEL / TEL + KIT.TEL.EC control panels |
|
TM |
|
Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TER.EC.BAC.M / TEL + KIT.TEL / TEL + KIT.TEL.EC control panels |
|
SA |
Air temperature probe for TER.ANA / TER.ANA.M / TER.EC.ANA / TER.EC.ANA.M / TER.DIG / TER.DIG.M / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TER.EC.BAC.M / TER.TOUCH / TER.EC.TOUCH control panels, used when the room temperature needs to be measured in a location other than the installed control panel |
|
SA |
|
Air temperature probe for TER.ANA / TER.ANA.M / TER.EC.ANA / TER.EC.ANA.M / TER.DIG / TER.DIG.M / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TER.EC.BAC.M / TER.TOUCH / TER.EC.TOUCH control panels, used when the room temperature needs to be measured in a location other than the installed control panel |
|
ATT.230 |
On/Off actuator for water valve, powered by 230 V |
|
ATT.230 |
|
On/Off actuator for water valve, powered by 230 V |
|
ATT.230.M |
On/Off actuator for water valve, powered by 230 V, with limit switch |
|
ATT.230.M |
|
On/Off actuator for water valve, powered by 230 V, with limit switch |
|
ATT.MOD |
Modulating by 0-10 V signal actuator for water valve |
|
ATT.MOD |
|
Modulating by 0-10 V signal actuator for water valve |
|
VAL.2V.34.CL |
2-way water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units, 3/4" connection |
|
VAL.2V.34.CL |
|
2-way water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units, 3/4" connection |
|
VAL.3V.34.CL |
3-way water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units, 3/4" connection |
|
VAL.3V.34.CL |
|
3-way water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units, 3/4" connection |
|
VAL.DIN.P.34.CL |
Balancing water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI fan coil units, 3/4" connection (1850 l/h) |
|
VAL.DIN.P.34.CL |
|
Balancing water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI fan coil units, 3/4" connection (1850 l/h) |
|
VAL.DIN.P.10.CL |
Balancing water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI fan coil units, 1" connection (3300 l/h) |
|
VAL.DIN.P.10.CL |
|
Balancing water valve for PS-CL/CLE/CLES/CLH/CLEH/CLEI fan coil units, 1" connection (3300 l/h) |
|
BAC.VAL1 |
Auxiliary drain pan for valve of PS-CL/CLE/CLES/CLH/CLEH/CLEHS/CLEI/CLQ fan coil units |
|
BAC.VAL1 |
|
Auxiliary drain pan for valve of PS-CL/CLE/CLES/CLH/CLEH/CLEHS/CLEI/CLQ fan coil units |
|
FL.RIN |
Fresh air inlet flange for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units |
|
FL.RIN |
|
Fresh air inlet flange for PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units |
|
FL.AIR |
Flange for air supply to the adjacent room, fits PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units |
|
FL.AIR |
|
Flange for air supply to the adjacent room, fits PS-CL/CLE/CLES/CLH/CLEH/CLEI/CLQ fan coil units |
|
KIT.RES.050 |
1.5 kW power electric heating element for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH/CLEHS/CLEI fan coil units |
|
KIT.RES.050 |
|
1.5 kW power electric heating element for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH/CLEHS/CLEI fan coil units |
|
PAN.MET.RAL.050 |
Painting of metal diffuser in non-standard RAL color for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units |
|
PAN.MET.RAL.050 |
|
Painting of metal diffuser in non-standard RAL color for 050 - 094 size PS-CL/CLE/CLES/CLH/CLEH fan coil units |