KITA AIR - reversible, Air/Air, in the heating mode it takes heat from the Outdoor Air and transfers it to the Indoor Air, in cooling mode it takes heat from the Indoor Air and transfers it to the Outdoor Air, consists of outdoor and indoor unit
KITA AIR OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR
OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR COLD OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR COLD
OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR PLUS OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR PLUS
OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR DUCTED OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR DUCTED
OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR COLD DUCTED OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR COLD DUCTED
OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR PLUS DUCTED OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR PLUS DUCTED
OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
MODEL Heating Cooling
A 12°C / A 20°C A 7°C / A 20°C A 2°C / A 20°C A -7°C / A 20°C A -15°C / A 20°C A -20°C / A 20°C A 35°C / A 27°C
Qh COP Qh COP Qh COP Qh COP Qh COP Qh COP Qc EER
kW kW kW kW kW kW kW
KITA AIR 39,00 4,70 39,00 4,45 35,00 3,75 32,00 3,20 32,00 2,70 27,00 2,50 35,00 4,02
KITA AIR COLD 40,00 4,63 40,00 4,36 35,00 4,00 35,00 3,10 35,00 2,60 30,00 2,35 37,00 4,20
KITA AIR PLUS 48,00 4,81 47,00 4,20 45,00 3,84 42,00 3,04 35,00 2,65 31,00 2,45 39,00 4,00

KITA AIR electric heat pump Air/Air
Manuals 11.8 MB
Brochures 2.2 MB
MULTI-AIR digital control panel for centralized control of KITA AIR heat pumps
Manuals 2 MB