Electric heat pump, reversible, Air/Air, in the heating mode it takes heat from the Outdoor Air and transfers it to the Indoor Air, in cooling mode it takes heat from the Indoor Air and transfers it to the Outdoor Air, consists of outdoor and indoor unit, OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
Interested in this product? Contact us:

Arvydas Palivonas

LT, RU, EN
+370 601 74426

Sales representative for Vilnius, Ukmergė, Utena, Kaišiadorys and Varėna regions Get Offer

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Sales representative for Kaunas, Panevėžys, Šiauliai, Telšiai, Klaipėda, Tauragė, Marijampolė and Alytus districts Get Offer
Click on the Model for technical data, dimensions, accessories
KITA AIR - reversible, Air/Air, in the heating mode it takes heat from the Outdoor Air and transfers it to the Indoor Air, in cooling mode it takes heat from the Indoor Air and transfers it to the Outdoor Air, consists of outdoor and indoor unit
KITA AIR OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR
OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR COLD OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR COLD
OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR PLUS OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR PLUS
OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR DUCTED OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR DUCTED
OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR COLD DUCTED OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR COLD DUCTED
OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR PLUS DUCTED OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR PLUS DUCTED
OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
Model: KITA AIR
General data
Nominal heating output at 7°C outdoor and 20°C indoor air temperature
kW
39,0
Nominal heating output at -7°C outdoor and 20°C indoor air temperature
kW
32,0
COP - heating coefficient of performance at 7°C outdoor and 20°C indoor air temperature
4,45
COP - heating coefficient of performance at -7°C outdoor and 20°C indoor air temperature
3,20
Nominal cooling output at 35°C outdoor and 27°C indoor air temperature
kW
35,0
EER - cooling energy efficiency ratio at 35°C outdoor and 27°C indoor air temperature
4,02
Max. electrical power consumption
kW
15,035
Compressor system
Type
Inverter steam injection scroll
Refrigerant type
R32
Refrigerant GWP
675
Refrigerant quantity if distance between outdoor and indoor unit does not exceed 10 m
kg
7,4
Outdoor unit data
Max. electrical power consumption
kW
14,2
Fan type
Inverter BLDC (Brushless DC)
Nominal fan diameter
mm Ø
910
Max. fan rotation speed
rpm
640
Max. fan power consumption
kW
0,7
Max. fan current consumption
A
1,1
Max. air flow
m³/h
17203
Max. acoustic pressure level at a distance of 5 m from the unit
dB(A)
38
Indoor unit data
Air delivery type
Direct horizontal air blowing
Fan type
Inverter BLDC (Brushless DC)
Nominal fan diameter
mm Ø
800
Max. fan rotation speed
rpm
735
Max. electrical power consumption
kW
0,835
Max. electrical current consumption
A
1,4
Min. air flow
m³/h
5800
Max. air flow
m³/h
14000
Air throw distance
m
25
Max. acoustic pressure level at a distance of 3 m from the unit
dB(A)
42
Number of heat exchanger rows
3
Heat exchanger fin spacing
mm
1,7
Installation data
Power supply
V / Hz / Ph
400 / 50 / 3
Max. electrical power consumption
kW
15,035
Gas coolant connection diameter
Ø mm (")
22 (7/8)
Liquid coolant connection diameter
Ø mm (")
16 (5/8)
Max. coolant connection length between outdoor and indoor unit
m
30
Operating temperature range in heating mode
°C
-25 / +28
Operating temperature range in cooling mode
°C
+5 / +45
Outdoor unit dimensions
Width
mm
1791
Depth
mm
725
Height
mm
1292
Weight
kg
285
Indoor unit dimensions
Width
mm
1253
Depth
mm
765
Height
mm
1090
Weight
kg
100

Dimensions

Model: KITA AIR
MODEL Heating Cooling
A 12°C / A 20°C A 7°C / A 20°C A 2°C / A 20°C A -7°C / A 20°C A -15°C / A 20°C A -20°C / A 20°C A 35°C / A 27°C
Qh COP Qh COP Qh COP Qh COP Qh COP Qh COP Qc EER
kW kW kW kW kW kW kW
KITA AIR 39,00 4,70 39,00 4,45 35,00 3,75 32,00 3,20 32,00 2,70 27,00 2,50 35,00 4,02
KITA AIR COLD 40,00 4,63 40,00 4,36 35,00 4,00 35,00 3,10 35,00 2,60 30,00 2,35 37,00 4,20
KITA AIR PLUS 48,00 4,81 47,00 4,20 45,00 3,84 42,00 3,04 35,00 2,65 31,00 2,45 39,00 4,00

KITA AIR electric heat pump Air/Air
Manuals 11.8 MB
Brochures 2.2 MB
MULTI-AIR digital control panel for centralized control of KITA AIR heat pumps
Manuals 2 MB